Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phytomedicine ; 107: 154450, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36174454

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) is an effective treatment for acute myocardial infarction, but the postoperative in-stent re-stenosis (ISR) remains a major risk factor that affects the prognosis of PCI. Clinically, drug-eluting stents (DES) are widely applied to prevent and treat ISR. However, only a few stent coating drugs are currently available for clinical use, including paclitaxel and rapamycin (sirolimus) and their derivatives. These stent-coated drugs have led to a decrease in restenosis rates, but the major adverse outcomes, such as delayed endothelial healing and increased in-stent thrombosis, seriously reduce their therapeutic effects. PURPOSE: Herein, we explored the potential efficacy of Euonymine (Euo), an alkaloid extracted from Tripterygium Hypoglaucum (Levl) Hutch (THH, Lei gong Teng), for the prevention against ISR after PCI. STUDY DESIGN: Our study depicts the potential efficacy of Euo in treating ISR and explores its mechanism with in vitro and in vivo models. METHODS: Primary vascular smooth muscle cells (VSMCs) from the rabbit thoracic aorta were cultured, and the proliferation and migration of VSMCs were monitored. Apoptosis was measured by Transmission Electron Microscopy and TUNEL staining assay. Protein and gene levels were measured to explore the underlying molecular mechanisms. In vivo models of porcine coronary implantation and rabbit carotid balloon injury are used to validate the efficacy of Euo in inhibiting ISR after PCI. RESULTS: With an ox-LDL-injured cell model, we showed that Euo suppressed the proliferation and migration of the rabbit thoracic aorta primary VSMCs, while inducing their apoptosis. We next established a rabbit carotid balloon injury model in which the phosphorylation levels of PI3K and AKT1 (Ser473) as well as mTOR activity were significantly elevated compared to the sham-operated control. These activities were significantly attenuated by the Euo intervention. Additionally, the balloon angioplasty significantly increased the expression of Bcl-2, while decreased the expression of Bax and caspase-3. Euo intervention significantly increased the ratio of Bax/Bcl-2 and the level of caspase-3. Taken together, Euo may enhance the VSMCs contractile phenotype by modulating the PTEN/AKT/mTOR signaling pathway. Furthermore, with two in vivo models, the porcine coronary artery implantation model, and the rabbit carotid balloon injury model, we demonstrated that Euo-eluting stents indeed inhibited ISR after PCI. CONCLUSION: For the first time, this study delineates the potential efficacy of Euo, derived from Tripterygium Hypoglaucum (Levl) Hutch, in ameliorating ISR after PCI with two in vivo models. The phytochemical targets PTEN/AKT/mTOR signaling pathway to increase the contractile phenotype of VSMCs and exerts anti-proliferative, anti-migratory as well as pro-apoptotic effects, thereby inhibiting the ISR.


Assuntos
Reestenose Coronária , Intervenção Coronária Percutânea , Animais , Caspase 3 , Constrição Patológica/complicações , Angiografia Coronária/efeitos adversos , Reestenose Coronária/tratamento farmacológico , Reestenose Coronária/etiologia , Músculo Liso Vascular , Paclitaxel , Intervenção Coronária Percutânea/efeitos adversos , Fenótipo , Fosfatidilinositol 3-Quinases , Proteínas Proto-Oncogênicas c-akt , Coelhos , Fatores de Risco , Transdução de Sinais , Sirolimo , Suínos , Serina-Treonina Quinases TOR , Resultado do Tratamento , Proteína X Associada a bcl-2
2.
J Imaging ; 7(9)2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34564114

RESUMO

Fast edge detection of images can be useful for many real-world applications. Edge detection is not an end application but often the first step of a computer vision application. Therefore, fast and simple edge detection techniques are important for efficient image processing. In this work, we propose a new edge detection algorithm using a combination of the wavelet transform, Shannon entropy and thresholding. The new algorithm is based on the concept that each Wavelet decomposition level has an assumed level of structure that enables the use of Shannon entropy as a measure of global image structure. The proposed algorithm is developed mathematically and compared to five popular edge detection algorithms. The results show that our solution is low redundancy, noise resilient, and well suited to real-time image processing applications.

3.
J Imaging ; 7(2)2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-34460627

RESUMO

The World Health Organization (WHO) has declared COVID-19 a pandemic. We review and reduce the clinical literature on diagnosis of COVID-19 through symptoms that might be remotely detected as of early May 2020. Vital signs associated with respiratory distress and fever, coughing, and visible infections have been reported. Fever screening by temperature monitoring is currently popular. However, improved noncontact detection is sought. Vital signs including heart rate and respiratory rate are affected by the condition. Cough, fatigue, and visible infections are also reported as common symptoms. There are non-contact methods for measuring vital signs remotely that have been shown to have acceptable accuracy, reliability, and practicality in some settings. Each has its pros and cons and may perform well in some challenges but be inadequate in others. Our review shows that visible spectrum and thermal spectrum cameras offer the best options for truly noncontact sensing of those studied to date, thermal cameras due to their potential to measure all likely symptoms on a single camera, especially temperature, and video cameras due to their availability, cost, adaptability, and compatibility. Substantial supply chain disruptions during the pandemic and the widespread nature of the problem means that cost-effectiveness and availability are important considerations.

4.
Eur J Pharmacol ; 906: 174200, 2021 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-34062170

RESUMO

Corilagin is a polyphenol has been identified anti-inflammatory properties. However, the anti-atherosclerotic effects of corilagin are not well understood. Here, we evaluated the anti-atherosclerotic effects and the underlying mechanisms of corilagin. We also verified whether corilagin can reverse atherosclerosis by regulating matrix metalloproteinase (MMP)-1, -2, and -9 in vitro and in vivo. An atherosclerosis model was established by feeding minipigs a high-fat diet combined with balloon injury, and the effects of different concentrations of corilagin on common carotid artery atherosclerosis in minipigs were monitored. Murine RAW264.7 macrophages were cultured and induced with oxidized low-density lipoprotein; fluorescence microscopy revealed the nuclear translocation of NF-κB. Furthermore, MMP-1, -2, and -9 expression in common carotid artery plaques and cellular models was detected by immunohistochemistry, western blotting, and RT-PCR. The pathological results suggested that the vascular intima of the model control group was significantly thickened, a large amount of collagen fibers was deposited, endothelial cells were damaged and detached, and plaque and foam cell formation occurred to varying degrees on the arterial wall, with lipid deposition. Corilagin treatment significantly reduced the degree of injury in the common carotid artery and decreased the number of lipid plaques and foam cells. Additionally, corilagin downregulated MMP-1, -2, and -9 expression in the common carotid artery plaques and cellular model. Moreover, corilagin significantly inhibited NF-κB nuclear translocation in vitro. Overall, corilagin exerted substantial therapeutic effects on experimental atherosclerotic minipigs via the downregulation of MMP-1, -2, and -9 expression.


Assuntos
Aterosclerose/tratamento farmacológico , Artéria Carótida Primitiva/patologia , Glucosídeos/farmacologia , Taninos Hidrolisáveis/farmacologia , Inibidores de Metaloproteinases de Matriz/farmacologia , Animais , Aterosclerose/etiologia , Aterosclerose/patologia , Artéria Carótida Primitiva/efeitos dos fármacos , Artéria Carótida Primitiva/metabolismo , Dieta Hiperlipídica/efeitos adversos , Modelos Animais de Doenças , Glucosídeos/uso terapêutico , Humanos , Taninos Hidrolisáveis/uso terapêutico , Masculino , Metaloproteinase 1 da Matriz/metabolismo , Metaloproteinase 2 da Matriz/metabolismo , Metaloproteinase 9 da Matriz/metabolismo , Inibidores de Metaloproteinases de Matriz/uso terapêutico , Camundongos , Células RAW 264.7 , Suínos , Porco Miniatura
5.
Sensors (Basel) ; 19(24)2019 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-31835550

RESUMO

Monitoring the cardiopulmonary signal of animals is a challenge for veterinarians in conditions when contact with a conscious animal is inconvenient, difficult, damaging, distressing or dangerous to personnel or the animal subject. In this pilot study, we demonstrate a computer vision-based system and use examples of exotic, untamed species to demonstrate this means to extract the cardiopulmonary signal. Subject animals included the following species: Giant panda (Ailuropoda melanoleuca), African lions (Panthera leo), Sumatran tiger (Panthera tigris sumatrae), koala (Phascolarctos cinereus), red kangaroo (Macropus rufus), alpaca (Vicugna pacos), little blue penguin (Eudyptula minor), Sumatran orangutan (Pongo abelii) and Hamadryas baboon (Papio hamadryas). The study was done without need for restriction, fixation, contact or disruption of the daily routine of the subjects. The pilot system extracts the signal from the abdominal-thoracic region, where cardiopulmonary activity is most likely to be visible using image sequences captured by a digital camera. The results show motion on the body surface of the subjects that is characteristic of cardiopulmonary activity and is likely to be useful to estimate physiological parameters (pulse rate and breathing rate) of animals without any physical contact. The results of the study suggest that a fully controlled study against conventional physiological monitoring equipment is ethically warranted, which may lead to a novel approach to non-contact physiological monitoring and remotely sensed health assessment of animals. The method shows promise for applications in veterinary practice, conservation and game management, animal welfare and zoological and behavioral studies.


Assuntos
Abdome/fisiologia , Fenômenos Fisiológicos Cardiovasculares , Monitorização Fisiológica , Gravação em Vídeo/métodos , Abdome/diagnóstico por imagem , Animais , Camelídeos Americanos/fisiologia , Sistema Cardiovascular/diagnóstico por imagem , Hospitais Veterinários , Humanos , Leões/fisiologia , Macropodidae/fisiologia , Papio/fisiologia , Phascolarctidae/fisiologia , Projetos Piloto , Spheniscidae/fisiologia , Tigres/fisiologia , Ursidae/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...